Raising The Plateau Level In Valley-Fill PFC Circuits Improves Efficiency

by Viktor Vogman, Power Conversion Consulting, Olympia, Wash., How2Power Today, May 15 2021

Focus:
To meet the IEC 61000-3-2 EMC standard’s limits on harmonic currents, passive power factor correction (PFC) is typically applied in class C and D equipment. The passive capacitive PFC circuit, which employs capacitor-diode networks in the valley-fill (VF) PFC configuration, can improve power factor and reduce harmonic distortion of the input line current with a reduction in volume versus active PFC. However, operation of the conventional VF-PFC circuit causes excessive supply voltage variations resulting in higher current magnitudes and higher power dissipation in the power conversion stages that follow the PFC stage. After reviewing the operation, characteristics and benefits of conventional VF-PFC circuits, in which the plateau level is typically one half of the peak ac voltage or less, this article discusses the efficiency improvement made possible by a novel implementation in which a higher plateau level is employed. An analysis of power losses in the dc-dc converter that follows the VF-PFC reveals which higher plateau levels are optimum in practice.

What you’ll learn: