How2power.com

Optimize Half-Bridge Circuit Designs Through Accurate VGS Measurements

by Tom Neville, Tektronix, Beaverton, Ore, How2Power Today, Jun 15 2016

Focus:
Use of a new galvanically isolated measurement system (Tektronix's IsoVu) improves the accuracy of high-side gate-source voltage (Vgs) measurements in power supply circuits. This improvement opens up new opportunities such as the ability to optimize half-bridge circuits, particularly at higher switching frequencies and higher voltages. IsoVu's key strength is its high common- mode rejection across its entire bandwidth. This enables more-accurate measurement of the high- side FET Vgs waveform during FET turn-on as well as more accurate measurement of high-side Vgs and low-side Vgs waveforms during high-side turn-off/low-side turn-on. The article discusses the characteristics of the Vgs waveforms and the limitations of existing instruments in measuring these waveforms. The features and key specs of IsoVu are described, IsoVu measurements of Vgs waveforms are presented, and these results are discussed.

What you’ll learn:

View this Source (requires a PDF Viewer installed on your device)